Free, timed, scored by domain. No sign-up.

Free CBSPD Practice Test: CSPDT Sterile Processing, Timed and Scored

This free CBSPD practice test has 25 original sterile processing questions across all eight domains of the CBSPD technician (CSPDT) exam, weighted like the CBSPD test specifications and timed at the exam's pace. Submit it for an instant score by domain, an explanation for every question and a list of what to study next. No sign-up.

The CSPDT (Certified Sterile Processing and Distribution Technician) exam is given by CBSPD, the Certification Board for Sterile Processing and Distribution. According to CBSPD, it has 125 questions plus 25 pretest questions in 3 hours, and Decontamination and Disinfection is the largest domain at 19%. This test is a short practice sample, not a full-length exam and not an official score. Taking the HSPA exam instead? Try the free CRCST practice test.

Free CBSPD Practice Test: 25 Timed Questions

30 minutes. About 1 minute 12 seconds per question, the pace of the CBSPD technician exam. Questions cover all eight domains in the CBSPD test specifications. Submit for an instant score by domain. No sign-up. These are original practice questions and do not reproduce the official exam.

Roles and Responsibilities

  1. Instructions for use1. A device manufacturer's instructions for use (IFU) differ from the way your department has always cleaned that device. What should you follow?
  2. Workplace hazards2. Where do you find the hazards, required PPE and first aid steps for a chemical used in decontamination?
  3. Loaner instrumentation3. Why should vendor loaner trays arrive well before the scheduled surgery?

Life Science

  1. Biofilm4. What is biofilm?
  2. Medical terminology5. An arthroscopy set is used to look inside which part of the body?

Decontamination and Disinfection

  1. PPE in decontamination6. Which PPE is worn when manually cleaning instruments in decontamination?
  2. Lumened devices7. How should the channel of a lumened instrument be brushed?
  3. Detergent dilution8. A technician adds extra detergent to the sink because the instruments are very dirty. What is the effect?
  4. Disassembly9. An instrument is designed to come apart. How should it be cleaned?
  5. Testing cleaning equipment10. How is the cleaning performance of a mechanical washer-disinfector checked?

Preparation and Handling

  1. Instrument identification11. How do you tell a Kelly hemostat from a Crile hemostat of the same size?
  2. Insulated instruments12. How should insulated laparoscopic instruments be checked for insulation damage?
  3. Instrument lubrication13. Which lubricant is used on hinged instruments before steam sterilization?
  4. Rigid containers14. Before a rigid sterilization container is used, which parts should be checked?

Sterilization

  1. Steam cycle parameters15. Which is a common prevacuum steam cycle for wrapped instruments, when the IFU allows it?
  2. Monitoring16. The sterilizer printout showing time, temperature and pressure for a cycle is which kind of monitoring?
  3. Hydrogen peroxide sterilization17. Which packaging material cannot go into a hydrogen peroxide gas sterilizer?
  4. Positive biological indicator18. A biological indicator from a steam load reads positive. What should happen next?
  5. Chemical indicator types19. Indicator tape on the outside of a wrapped pack is which type of chemical indicator?

Sterile Storage, Inventory Management and Distribution

  1. Issuing sterile items20. Before a sterile package is issued, what should be checked?
  2. Inventory levels21. What is the term for the set amount of an item kept on hand, which tells staff when to restock?
  3. Transport22. How should sterile items be transported to the operating room on a cart?

Patient Care Equipment

  1. Disinfectant contact time23. A disinfectant label lists a contact time for wiping patient care equipment. What does that mean?

Ethics

  1. Reporting errors24. A technician drops a sterile tray on the floor and no one sees it happen. What is the right action?
  2. Documentation25. At the end of the shift, a technician sees that a sterilizer log entry was missed earlier. What is acceptable?

CBSPD technician exam domains

The share of the exam in each domain, from the CBSPD technician test specifications.

Roles and Responsibilities13%

Workplace hazards and ergonomics, policies and procedures, OSHA, FDA, CDC and EPA rules, professional standards, workflow, loaner instruments, following instructions for use

Life Science9%

Microbiology and biofilm, how disease spreads, types of microorganisms, anatomy and physiology, medical terminology

Decontamination and Disinfection19%

Chemicals, high-level disinfectants and sterilants, PPE, cleaning equipment and its testing, sorting and cleaning instruments, instrument handling

Preparation and Handling16%

Instrument names, types and construction, inspection and testing, tray assembly, packaging materials, sterilization monitors, tamper-evident seals

Sterilization18%

Sterilizer types and methods, cycles and parameters, quality assurance testing, operating sterilizers, lot control and records, wet packs, recalls

Sterile Storage, Inventory Management and Distribution11%

Shelf life, storage, stock rotation, inventory, distribution systems, receiving, cart tracking

Patient Care Equipment6%

Collecting, disinfecting, storing and distributing patient care equipment

Ethics8%

Regulatory compliance and reporting, professional behavior

CBSPD technician exam FAQ

Is this CBSPD practice test free?
Yes. All 25 questions, the timer, your score by domain, the explanation for every question and the list of what to study next are free, with no sign-up. An email box after your score is optional.
What is on the CBSPD technician (CSPDT) exam?
According to the CBSPD technician test specifications, the exam covers eight domains: Decontamination and Disinfection (19%), Sterilization (18%), Preparation and Handling (16%), Roles and Responsibilities (13%), Sterile Storage, Inventory Management and Distribution (11%), Life Science (9%), Ethics (8%) and Patient Care Equipment (6%).
How many questions are on the CBSPD technician exam, and how long is it?
According to the CBSPD Technician Candidate Bulletin, the exam has 125 questions plus 25 pretest questions, 150 in all, and you have 3 hours. That is about 1 minute 12 seconds per question, the pace this free test uses.
Who can take the CBSPD technician exam?
According to the CBSPD bulletin, you qualify through one of several routes, such as 12 months of full-time sterile processing work, a sterile processing training course passed with a grade of 70 or higher, or a mix of allied health and sterile processing work. Check the current bulletin for the full list and the proof each route needs.
Where and when do you take the CBSPD exam?
According to the CBSPD bulletin, the technician exam is computer-based at PSI testing centers during set testing windows through the year, and you test at the center you are assigned. The exam is given in English.
What is the difference between CBSPD and CRCST certification?
Both certify sterile processing technicians. The CSPDT technician certification is given by CBSPD (Certification Board for Sterile Processing and Distribution), and CRCST is given by HSPA (Healthcare Sterile Processing Association). Their outlines cover much of the same work. Ask your employer or program which one it accepts.
Is this the official CBSPD practice test?
No. These are 25 original practice questions written by StudyBuddy, not CBSPD questions, and the test is a short sample, not a full-length exam. Your score here is practice feedback, not a prediction of your CBSPD result.

CSPDT is a certification of the Certification Board for Sterile Processing and Distribution (CBSPD). StudyBuddy is not affiliated with or endorsed by CBSPD. Exam facts on this page are from CBSPD's published technician test specifications and candidate bulletin.